0.3 ″ For interpolation of the sine/cosine signals with, e. g., 12 bits
Integral non-linearity
Typ. ± 45 ″, Error limits for evaluating sine/cosine period
Differential non-linearity
± 7 ″
Operating speed
≤ 6,000 min⁻¹, up to which the absolute position can be reliably produced
Available memory area
128 Byte
System accuracy
± 52 ″
Interfaces
Type of code for the absolute value
Binary
Code sequence
Increasing, when turning the shaft For clockwise rotation, looking in direction “A” (see dimensional drawing), For clockwise shaft rotation, looking in direction “A” (see dimensional drawing)