Tecnichal data
| Number of contacts as normally closed contact | 3 |
| Number of contacts as normally open contact | 1 |
| With status indication | No |
| Type of electric connection | Other |
| Utilization category | N600/DC-13 |
| Switching current, min | 5 mA @ 5V DC |
| Auxiliary contacts | 1NO (with 2 NC) |
| Contact current rating (Ie) | 6 A @ 120V AC (Ue) |
| Thermal current (Ith) | 10 A |
| Actuation speed, min | 100 mm/min |
| Actuation speed, max | 250 mm/s |
| Rated impulse withstand voltage | 2500 V |
| Actuation frequency, max | 6000 ops/hr |
| Rated insulation voltage | 600V AC |
| Suitable for safety functions | Yes |
| Forced opening | Yes |
| Degree of protection (NEMA) | 1 |
| Material housing | Metal |
| Degree of protection (IP) | IP66 |
| Contact type | Break before make |
| Enclosure color | Red |
| Mounting | 2 x M5, any position |
| Body style | 30 mm large metal body |
| Width | 40 mm |
| Height | 105 mm |
| Actuator type | Dome plunger |
| Mechanical life operations | 10000000 operations per hour |
| Housing material | Die-cast alloy |
| Connection type | M20 conduit |
| Construction type housing | Cuboid |
| Depth | 43 mm |
| Actuator material | Various polymers and metals |
| Operating temperature | -25 ðC |
| Safety contacts | 1 NC snap acting, 2 NC, 3 NC or 4 NC slow acting |
| Pollution degree | 3 |
| Shock | IEC 60068-2-7 (30 Gn 3 pulses per axis) |
| Vibration | IEC 60068-2-6 (10…55 Hz, 0.35 mm amplitude) |