Tecnichal data
| Number of contacts as normally closed contact | 1 |
| Number of contacts as normally open contact | 1 |
| Suitable for illumination | Yes |
| Lamp type | Incandescent lamp |
| Rated supply voltage | 120V AC, 50/60 Hz |
| Rated operational current | 69VA @ 28…600V DC |
| Rated operational current, break | 720VA @ 72…120V AC |
| Rated operational current, make | 7200VA @ 120…600V AC |
| Power module type | Transformer or dual input |
| Operational voltage (Ue), max | 600V AC, 600V DC |
| Thermal continuous current (Ith), max | 10 A AC, 2.5 A DC |
| Utilization category | AC-15 per IEC, DC-13 per IEC |
| Lamp test type | Push-to-test |
| Dielectric strength | 2200V for 1 minute, 1300V for 1 minute (Logic Reed) |
| Electrical life cycle | 1000000 cycles at maximum rated load, 200000 cycles at maximum rated load (Logic Reed) |
| Spring-return | Yes |
| Hole diameter | 30.5 mm |
| Type of electric connection | Screw connection |
| Mechanical life operations | 200000 min |
| Typical operating forces with contact blocks | 800T-XA: 1 lb |
| Shock | 1/2 cycle sine wave for 11 ms ââ°¥25 G (contact fragility) and no damage at 100 G |
| Degree of protection | Type 7 & 9 explosion proof (Type 3 and Type 4 ratings available with accessories) |
| Vibration | 10…2000 Hz, 1.52 mm displacement (peak-to-peak) maximum/10 G maximum (except Logic Reed) |
| Switching function latching | No |
| Terminal screw torque | 6 lb.in |
| Wire gauge | 18 AWG |
| Typical operating force for illuminated push buttons and push-to-test pilot lights | 5.6 lb maximum |
| Material front ring | Plastic |
| Finger-safe guards | No guards on terminals |
| Lens color | Multi-color insert packet (amber, blue, green, red, white) |
| Contact block | For push-to-test: 1 NO, 1 NC, standard contact block (800T-XA) |
| With front ring | Yes |
| Construction type lens | Round |
| Operating temperature | -20 ðC |
| Humidity | 50% at 104 ðF (40 ðC) |
| Storage temperature | -40 ðC |