Home Akış (Flow) Sensörleri PFT-FAB2X5AF2OHCALSSZ – 6050900 🔍 PFT-FAB2X5AF2OHCALSSZ – 6050900 ✉ Teklif Al Teklif Al Stok kodu: 6050900 Kategoriler: Akış (Flow) Sensörleri Marka: SICK Açıklama Tecnichal data Features Medium Liquid, gaseous Pressure type Absolute pressure Pressure unit bar Measuring range 0 bar … 2.5 bar Process temperature –20 °C … +150 °C Maximum ohmic load RA 4 mA … 20 mA, 2-wire (RA ≤ (L+ – 10 V) / 0.02 A [Ohm]) 0 V … 5 V, 3-wire (RA > 5 kOhm) 0 V … 10 V, 3-wire (RA > 10 kOhm) Output signal 4 mA … 20 mA, 2-wire Specialty Without Mechanics/electronics Process connection G ½ B flush-mounted with O-ring Wetted parts Flush-mounted membrane: Stainless steel 1.4571 with NBR O-ring or FKM O-ring (FKM with integrated cooling element) Internal transmission fluid Synthetic oil (Not available for version with standard membrane for pressure ranges > 25 bar) Pressure port Front-flush membrane Housing material Stainless steel 1.4571 Connection type L-connector (DIN EN 175301-803 A) Supply voltage 10 V DC … 30 V DC Electrical safety Overvoltage protection: 36 V DC Short-circuit protection: QA towards M Reverse polarity protection: L+ to M Protection class: III Dielectric strength 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even in the event of a fault) CE-conformity Pressure equipment directive: 2014/68/EU EMC directive: 2004/108/EC, EN 61326-2-3 Weight sensor Approx. 200 g Seal FPM/FKM Enclosure rating IP65 Protection class III ✔ MTTF 403 years Performance Non-linearity ≤ ± 0.2 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2 Accuracy ≤ ± 0.25 % of the span Non-repeatability ≤ ± 0.1 % of the span Response time (10 % … 90 %) ≤ 1 ms ≤ 10 ms at medium temperatures below < –30°C for pressure ranges up to 25 bar or with flush-mounted membrane Long-term drift/one-year stability ≤ ± 0.2 % of span (at reference conditions) Temperature coefficient in rated temperature range Mean TC of zero: ≤ 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤ 0.25 bar) Mean TC of span ≤ 0.2 % of span / 10 K Rated temperature range 0 °C … +80 °C Service life Minimum 10 Mio. load cycles Ambient data Ambient temperature –20 °C … +80 °C Storage temperature –40 °C … +100 °C, with flush-mounted membrane and cooling element –20 °C … +100 °C Shock load 1000 g according to IEC 60068-2-27 (mechanical shock) 400 g according to IEC 60068-2-27 (mechanical shock) for version with integrated cooling element Vibration load 20 g according to IEC 60068-2-6 (vibration under resonance) 10 g according to IEC 60068-2-6 (vibration undencr resonae) for version with integrated cooling element Classifications eCl@ss 5.0 27200614 eCl@ss 5.1.4 27200614 eCl@ss 6.0 27200614 eCl@ss 6.2 27200614 eCl@ss 7.0 27200614 eCl@ss 8.0 27200614 eCl@ss 8.1 27200614 eCl@ss 9.0 27200614 eCl@ss 10.0 27200614 eCl@ss 11.0 27200614 eCl@ss 12.0 27200614 ETIM 5.0 EC011478 ETIM 6.0 EC011478 ETIM 7.0 EC011478 ETIM 8.0 EC011478 UNSPSC 16.0901 41112410 İlgili ürünler FUM-H015F1CB50000 – 1072035SICKAkış (Flow) Sensörleri ₺5.500,00 Ürüne Git FUM-H015F1NC80000 – 1082026SICKAkış (Flow) Sensörleri ₺5.500,00 Ürüne Git FUM-H025F1NE80000 – 1082035SICKAkış (Flow) Sensörleri ₺5.500,00 Ürüne Git FUM-H025F1CD50000 – 1082027SICKAkış (Flow) Sensörleri ₺5.500,00 Ürüne Git
Tecnichal data Features Medium Liquid, gaseous Pressure type Absolute pressure Pressure unit bar Measuring range 0 bar … 2.5 bar Process temperature –20 °C … +150 °C Maximum ohmic load RA 4 mA … 20 mA, 2-wire (RA ≤ (L+ – 10 V) / 0.02 A [Ohm]) 0 V … 5 V, 3-wire (RA > 5 kOhm) 0 V … 10 V, 3-wire (RA > 10 kOhm) Output signal 4 mA … 20 mA, 2-wire Specialty Without Mechanics/electronics Process connection G ½ B flush-mounted with O-ring Wetted parts Flush-mounted membrane: Stainless steel 1.4571 with NBR O-ring or FKM O-ring (FKM with integrated cooling element) Internal transmission fluid Synthetic oil (Not available for version with standard membrane for pressure ranges > 25 bar) Pressure port Front-flush membrane Housing material Stainless steel 1.4571 Connection type L-connector (DIN EN 175301-803 A) Supply voltage 10 V DC … 30 V DC Electrical safety Overvoltage protection: 36 V DC Short-circuit protection: QA towards M Reverse polarity protection: L+ to M Protection class: III Dielectric strength 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even in the event of a fault) CE-conformity Pressure equipment directive: 2014/68/EU EMC directive: 2004/108/EC, EN 61326-2-3 Weight sensor Approx. 200 g Seal FPM/FKM Enclosure rating IP65 Protection class III ✔ MTTF 403 years Performance Non-linearity ≤ ± 0.2 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2 Accuracy ≤ ± 0.25 % of the span Non-repeatability ≤ ± 0.1 % of the span Response time (10 % … 90 %) ≤ 1 ms ≤ 10 ms at medium temperatures below < –30°C for pressure ranges up to 25 bar or with flush-mounted membrane Long-term drift/one-year stability ≤ ± 0.2 % of span (at reference conditions) Temperature coefficient in rated temperature range Mean TC of zero: ≤ 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤ 0.25 bar) Mean TC of span ≤ 0.2 % of span / 10 K Rated temperature range 0 °C … +80 °C Service life Minimum 10 Mio. load cycles Ambient data Ambient temperature –20 °C … +80 °C Storage temperature –40 °C … +100 °C, with flush-mounted membrane and cooling element –20 °C … +100 °C Shock load 1000 g according to IEC 60068-2-27 (mechanical shock) 400 g according to IEC 60068-2-27 (mechanical shock) for version with integrated cooling element Vibration load 20 g according to IEC 60068-2-6 (vibration under resonance) 10 g according to IEC 60068-2-6 (vibration undencr resonae) for version with integrated cooling element Classifications eCl@ss 5.0 27200614 eCl@ss 5.1.4 27200614 eCl@ss 6.0 27200614 eCl@ss 6.2 27200614 eCl@ss 7.0 27200614 eCl@ss 8.0 27200614 eCl@ss 8.1 27200614 eCl@ss 9.0 27200614 eCl@ss 10.0 27200614 eCl@ss 11.0 27200614 eCl@ss 12.0 27200614 ETIM 5.0 EC011478 ETIM 6.0 EC011478 ETIM 7.0 EC011478 ETIM 8.0 EC011478 UNSPSC 16.0901 41112410