Home Seviye Sensörleri (Proses Tip) LFP0800-G1CMB – 1102899 🔍 LFP0800-G1CMB – 1102899 ✉ Teklif Al Teklif Al Stok kodu: 1102899 Kategoriler: Seviye Sensörleri (Proses Tip) Marka: SICK Açıklama Tecnichal data Features Medium Fluids Measurement Switch, Continuous Design Remote amplifier, length of cable 2 m Probe length 800 mm Process pressure –1 bar … 16 bar Process temperature –20 °C … +180 °C UL approval ✔ RoHS certificate ✔ IO-Link ✔ EHEDG approval ✔ Performance Accuracy of sensor element ± 5 mm Reproducibility ≤ 2 mm Resolution 1 mm Response time < 400 ms Dielectricity constant ≥ 5 for rod probe ≥ 1.8 with coaxial tube Conductivity No limitation Deactivated area at process connection 25 mm Deactivated area at end of probe ≥ 10 mm MTTF 194.3 years (EN ISO 13849-1) Display ✔ Electronics Supply voltage 12 V DC … 30 V DC Power consumption ≤ 75 mA at 24 V DC without output load Initialization time ≤ 2 s Protection class III Connection type Round connector M12 x 1, 5-pin Length of cable 2 m Output signal 1 x PNP + 1 x PNP/NPN + 4 mA … 20 mA / 0 V … 10 V Output load 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 0 V … 10 V > 750 Ohm at Uv 14 ≥ V Hysteresis Min. 2 mm, free adjustable Output current < 100 mA Inductive load < 1 H Capacitive load < 100 nF Enclosure rating IP67 / 69: EN 60529 Temperature drift < 0.1 mm/K Lower signal level 3.8 mA … 4 mA, 0 V Upper signal level 20 mA … 20.5 mA, 10.5 V EMC EN 61326-2-3, 2014/30/EU Mechanics Wetted parts 316L (Ra ≤ 0,8 µm), PEEK Process connection G ¾ A Housing material 303 Housing design With viewing window made from PMMA (acrylic glass) Max. probe load ≤ 6 Nm Material coaxial cable FEP Length coaxial cable 2 m Ambient data Ambient operating temperature –20 °C … +60 °C Ambient temperature, storage –40 °C … +80 °C Ambient temperature coaxial cable –20 °C … +60 °C Outdoor use Only with weather hood Classifications ECLASS 5.0 27200513 ECLASS 5.1.4 27200513 ECLASS 6.0 27200513 ECLASS 6.2 27200513 ECLASS 7.0 27200513 ECLASS 8.0 27200513 ECLASS 8.1 27200513 ECLASS 9.0 27200513 ECLASS 10.0 27200513 ECLASS 11.0 27200513 ECLASS 12.0 27200513 ETIM 5.0 EC001447 ETIM 6.0 EC001447 ETIM 7.0 EC001447 ETIM 8.0 EC001447 UNSPSC 16.0901 41113710 İlgili ürünler LFP0400-B5NMC – 1062266SICKSeviye Sensörleri (Proses Tip) ₺4.200,00 Ürüne Git LFP0600-A5NMC – 1062249SICKSeviye Sensörleri (Proses Tip) ₺4.200,00 Ürüne Git LFP1900-A5NMC – 1062262SICKSeviye Sensörleri (Proses Tip) ₺4.200,00 Ürüne Git LFP2000-A5NMC – 1062263SICKSeviye Sensörleri (Proses Tip) ₺4.200,00 Ürüne Git
Tecnichal data Features Medium Fluids Measurement Switch, Continuous Design Remote amplifier, length of cable 2 m Probe length 800 mm Process pressure –1 bar … 16 bar Process temperature –20 °C … +180 °C UL approval ✔ RoHS certificate ✔ IO-Link ✔ EHEDG approval ✔ Performance Accuracy of sensor element ± 5 mm Reproducibility ≤ 2 mm Resolution 1 mm Response time < 400 ms Dielectricity constant ≥ 5 for rod probe ≥ 1.8 with coaxial tube Conductivity No limitation Deactivated area at process connection 25 mm Deactivated area at end of probe ≥ 10 mm MTTF 194.3 years (EN ISO 13849-1) Display ✔ Electronics Supply voltage 12 V DC … 30 V DC Power consumption ≤ 75 mA at 24 V DC without output load Initialization time ≤ 2 s Protection class III Connection type Round connector M12 x 1, 5-pin Length of cable 2 m Output signal 1 x PNP + 1 x PNP/NPN + 4 mA … 20 mA / 0 V … 10 V Output load 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 0 V … 10 V > 750 Ohm at Uv 14 ≥ V Hysteresis Min. 2 mm, free adjustable Output current < 100 mA Inductive load < 1 H Capacitive load < 100 nF Enclosure rating IP67 / 69: EN 60529 Temperature drift < 0.1 mm/K Lower signal level 3.8 mA … 4 mA, 0 V Upper signal level 20 mA … 20.5 mA, 10.5 V EMC EN 61326-2-3, 2014/30/EU Mechanics Wetted parts 316L (Ra ≤ 0,8 µm), PEEK Process connection G ¾ A Housing material 303 Housing design With viewing window made from PMMA (acrylic glass) Max. probe load ≤ 6 Nm Material coaxial cable FEP Length coaxial cable 2 m Ambient data Ambient operating temperature –20 °C … +60 °C Ambient temperature, storage –40 °C … +80 °C Ambient temperature coaxial cable –20 °C … +60 °C Outdoor use Only with weather hood Classifications ECLASS 5.0 27200513 ECLASS 5.1.4 27200513 ECLASS 6.0 27200513 ECLASS 6.2 27200513 ECLASS 7.0 27200513 ECLASS 8.0 27200513 ECLASS 8.1 27200513 ECLASS 9.0 27200513 ECLASS 10.0 27200513 ECLASS 11.0 27200513 ECLASS 12.0 27200513 ETIM 5.0 EC001447 ETIM 6.0 EC001447 ETIM 7.0 EC001447 ETIM 8.0 EC001447 UNSPSC 16.0901 41113710