Home Işık Perdeleri LBR-IJUTDBOHAAX – 6080286 🔍 LBR-IJUTDBOHAAX – 6080286 ✉ Teklif Al Teklif Al Stok kodu: 6080286 Kategoriler: Işık Perdeleri Marka: SICK Açıklama Tecnichal data Features Medium Bulk solids Measurement Continuous Probe type Thread with integrated horn antenna made from PEEK Frequency band W-band (within 75 … 85 GHz) Measuring range Up to 120 m (393.7 ft), recommended measuring range in thread version with integrated horn antenna up to 20 m (65.62 ft) Angle of dispersion 7° Process pressure –1 bar … 20 bar(-100 kPa … 2,000 kPa / –14.5 psig … 290.1 psig) Process temperature –40 °C … +200 °C ATEX approval IEC Ex db IIC T6…T1, Ga/Gb, Gb, IEC Ex ta, ta/tb, ta/tc, tb IIIC T* Da, Da/Db, Da/Dc, Db Type examination IECEx KIWA 20.0015X, IECEx KIWA 20.0016X RoHS certificate ✔ HART ✔ Indication Installed Control element Pushbutton operation Performance Accuracy of sensor element ≤ 5 mm Non-repeatability ≤ 1 mm Digital measurement resolution < 1 mm Analog measurement resolution 0.3 µA Digital output temperature drift ≤ 3 mm / 10 K, max. 10 mm Current output temperature drift ≤ 0.03% / 10 K relating to the 16 mA span or ≤ 0.3% Deviation on current output due to digital-analog conversion < 15 µA Measurement cycle time Approx. 700 ms Step response time ≤ 3 s MTBF 3,37*10^6 h Display ✔ Electronics Supply voltage 9 V DC … 30 V DC Protection class I (IEC 61010-1) Connection type M20 x 1.5 / cable gland nickel-plated brass (ø 6 mm – 12 mm) Output signal 4 mA … 20 mA / HART Contamination rating 4 Enclosure rating IP66 / IP68 EMC EN 61326-1 Start-up current < 3.6 mA Overvoltage category III (IEC 61010-1) Short-circuit protection ✔ Isolation ✔ Mechanics Process connection Thread 1 ½” NPT PN20, ASME B1.20.1 / 316L Housing material Aluminum die cast AlSi10Mg, powder-coated (base: polyester) Housing design Single-chamber housing Sealing material FKM (SHS FPM 70C3 GLT) Antenna material PEEK Ambient data Ambient operating temperature –40 °C … +80 °C Ambient temperature, storage –40 °C … +80 °C Classifications ECLASS 5.0 27200505 ECLASS 5.1.4 27200505 ECLASS 6.0 27200505 ECLASS 6.2 27200505 ECLASS 7.0 27200505 ECLASS 8.0 27200505 ECLASS 8.1 27200505 ECLASS 9.0 27200505 ECLASS 10.0 27270807 ECLASS 11.0 27270807 ECLASS 12.0 27274501 ETIM 5.0 EC001447 ETIM 6.0 EC001447 ETIM 7.0 EC001447 ETIM 8.0 EC001447 UNSPSC 16.0901 41111950 İlgili ürünler Transceiver, LineE 1050 – 14mm, Product line E, Type4/Cat.4, 14mm Finger resolution, Protective height: 1050 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4FL1050YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git Transceiver, LineE 1650 – 30mm, Product line E, Type4/Cat.4, 30mm Hand resolution, Protective height: 1650 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4HL1650YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git Transceiver, LineE 1500 – 14mm, Product line E, Type4/Cat.4, 14mm Finger resolution, Protective height: 1500 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4FL1500YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git Transceiver, LineE 300 – 30mm, Product line E, Type4/Cat.4, 30mm Hand resolution, Protective height: 300 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4HL0300YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git
Tecnichal data Features Medium Bulk solids Measurement Continuous Probe type Thread with integrated horn antenna made from PEEK Frequency band W-band (within 75 … 85 GHz) Measuring range Up to 120 m (393.7 ft), recommended measuring range in thread version with integrated horn antenna up to 20 m (65.62 ft) Angle of dispersion 7° Process pressure –1 bar … 20 bar(-100 kPa … 2,000 kPa / –14.5 psig … 290.1 psig) Process temperature –40 °C … +200 °C ATEX approval IEC Ex db IIC T6…T1, Ga/Gb, Gb, IEC Ex ta, ta/tb, ta/tc, tb IIIC T* Da, Da/Db, Da/Dc, Db Type examination IECEx KIWA 20.0015X, IECEx KIWA 20.0016X RoHS certificate ✔ HART ✔ Indication Installed Control element Pushbutton operation Performance Accuracy of sensor element ≤ 5 mm Non-repeatability ≤ 1 mm Digital measurement resolution < 1 mm Analog measurement resolution 0.3 µA Digital output temperature drift ≤ 3 mm / 10 K, max. 10 mm Current output temperature drift ≤ 0.03% / 10 K relating to the 16 mA span or ≤ 0.3% Deviation on current output due to digital-analog conversion < 15 µA Measurement cycle time Approx. 700 ms Step response time ≤ 3 s MTBF 3,37*10^6 h Display ✔ Electronics Supply voltage 9 V DC … 30 V DC Protection class I (IEC 61010-1) Connection type M20 x 1.5 / cable gland nickel-plated brass (ø 6 mm – 12 mm) Output signal 4 mA … 20 mA / HART Contamination rating 4 Enclosure rating IP66 / IP68 EMC EN 61326-1 Start-up current < 3.6 mA Overvoltage category III (IEC 61010-1) Short-circuit protection ✔ Isolation ✔ Mechanics Process connection Thread 1 ½” NPT PN20, ASME B1.20.1 / 316L Housing material Aluminum die cast AlSi10Mg, powder-coated (base: polyester) Housing design Single-chamber housing Sealing material FKM (SHS FPM 70C3 GLT) Antenna material PEEK Ambient data Ambient operating temperature –40 °C … +80 °C Ambient temperature, storage –40 °C … +80 °C Classifications ECLASS 5.0 27200505 ECLASS 5.1.4 27200505 ECLASS 6.0 27200505 ECLASS 6.2 27200505 ECLASS 7.0 27200505 ECLASS 8.0 27200505 ECLASS 8.1 27200505 ECLASS 9.0 27200505 ECLASS 10.0 27270807 ECLASS 11.0 27270807 ECLASS 12.0 27274501 ETIM 5.0 EC001447 ETIM 6.0 EC001447 ETIM 7.0 EC001447 ETIM 8.0 EC001447 UNSPSC 16.0901 41111950