Tecnichal data
| Number of normally open contacts as main contact | 4 |
| Number of normally closed contacts as main contact | 0 |
| Number of auxiliary contacts as normally open contact | 0 |
| Number of auxiliary contacts as normally closed contact | 0 |
| Vibration resistance | IEC 60068-2-6 |
| Shock resistance | IEC 60068-2-27 |
| Altitude, max | 3000 m of installation site |
| Switching frequency, max | 600 ops/hr, AC-1 |
| Weight | AC/DC (electronic): 0.43 kg (0.95 lbs.) |
| Protection class | Contactor main contact: IP2X |
| Voltage type for actuating | DC |
| Rated control supply voltage at DC | 12 V |
| Type of electrical connection of main circuit | Screw connection |
| Rated impulse voltage withstand (Uimp) | 6 kV |
| Operating time, closing delay | 40 ms |
| Optional overload relays | Electronic |
| Main current circuit resistance | 0.41 mé |
| Rated isolation voltage (Ui) | 690V per IEC |
| Function | Non-reversing contactor |
| Energy-efficient coil, hold-in | 1.7 @ 12-20V DC |
| Energy-efficient coil, pick-up | 12 W…16 W @ 12-20V DC |
| General purpose current (enclosed) | 13.8 A @ 600V per UL/CSA |
| Power dissipation | 0.8 W per pole at Ie, AC-1, 400V |
| FLA | 20 A @ 600V, 3-phase per UL/CSA HVAC applications |
| Rated operational current and power (enclosed) | 9.5 A @ 125V DC, with 3-poles in series per UL/CSA |
| LRA | 80 A @ 550-600V, 3-phase AC per UL/CSA HVAC applications |
| Electromagnetic compatibility | IEC 60947-1 – Environment A and B (100-E09…E38 only) |
| Total power dissipation | 2.3 W at Ie, AC-3, 400V, AC/DC control (120-250V) |
| Operating limits, dropout | (ââ°¤0.60) x Us @ DC control |
| Operating limits, pick-up | (0.85…1.1) x Us @ 50/60 Hz |
| MCCB current rating | Type 2 (per IEC 60947-4-1): 28 A @ 400V, 70 kA available fault current |
| DIN fuses (gG) current rating | Type 2 (per IEC 60947-4-1): 6 A @ 690 V, 60 kA available fault current |
| Rated voltage (Ue) | 24, 48, 110, 220, 440V DC |
| Rated operational current and power | 5.8 A @ 115V AC, 500000 electrical operations, 1-phase per UL/CSA elevator duty |
| Coil voltage | 12 to 20V DC |
| Switching of lighting loads | Tungsten lamps: 20 A @ 600V, 3-phase (break all lines) per UL/CSA |
| UL class RK5 fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30 A @ 600V, 5 kA available fault current |
| Rated operational current (Ie) | 9.5 A @ 500V, Star-Delta starting (50 Hz) |
| UL class J and CSA HRCI-J fuses rating | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30 A @ 600V, 100 kA available fault current |
| UL inverse-time circuit breaker | Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 5 kA available fault current |
| Switching of power transformers | Apparent power: 8 kVA @ 415V, AC-6a, 50 Hz (n = 30) |
| Rated operational power (Pe) | 9 kW @ 240V, AC-1 active power load (50/60 Hz), ambient temperature 70 ðC (158 ðF) |
| Switching of DC loads | 4-poles in series: 6 A @ 440V (Shunt-wound motors-starting, reverse current breaking, reversing, stepping: DC-3 at 60 ðC) |
| Optional accessories | Side-or front-mount auxiliary contacts, Mechanical interlocks, Connecting bars |
| Features | Panel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials |
| Climatic withstand | Category B according to IEC 60947-1, annex Q |
| Ambient temperature | Storage: -60 ðC…80 ðC (-76 ðF…176 ðF) |
| Coil insulation class | Class F per IEC 60947-4-1 |