± 1 % of measured value +/- 0.3% of measuring range limit value (with calibration log)
Repeatability
≤ 0.5 %
Calibration certificate
✔
Electronics
Supply voltage
18 V DC … 30 V DC
Residual ripple
≤ 5 Vpp
Power consumption
≤ 180 mA
Initialization time
≤ 5 s
Protection class
III
Connection type
Round connector M12 x 1, 5-pin
Output signal
Analog output 4 mA … 20 mA, 0 mA … 20 mA current flow and temperature1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type)
Output current
< 100 mA
Output load
< 500 Ohm
Lower signal level
3.8 mA … 4 mA
Upper signal level
20 mA … 20.5 mA
Impuls/frequency output
0 kHz … 10 kHz
Puls width
≤ 1 s
Inductive load
1 H
Capacitive load
100 nF
Response time
Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s