Tecnichal data
| Number of outputs, safety related, undelayed, with contact | 2 |
| Number of outputs, safety related, delayed, with contact | 3 |
| Number of outputs, signalling function, undelayed, with contact | 0 |
| Number of outputs, safety related, undelayed, semiconductors | 0 |
| Number of outputs, safety related, delayed, semiconductors | 0 |
| Number of outputs, signalling function, undelayed, semiconductors | 0 |
| Number of outputs, signalling function, delayed, semiconductors | 0 |
| With start input | Yes |
| Voltage type for actuating | AC/DC |
| Rated control supply voltage at DC | 24 V |
| Model | Basic device |
| Type of electric connection | Spring clamp connection |
| Evaluation inputs | One- and two-channel |
| Power ON delay | 1 ms |
| Input resistance, max | 135 Ohm |
| Power consumption | 4 W |
| Terminal type | Spring clamp |
| Fuses output | External: 6 A slow blow or 10 A quick blow |
| Rated thermal current (Ith) | 7 A maximum in one current path (non-switching) |
| Continuous safety output current | UL: B300, 5 A @ 250V AC, 24V AC/DC, AC-15: 6 A @ 250V AC, DC-13: 3 A @ 24V AC/DC |
| Wire size | 0.2 to 2.5 mmò |
| Electrical life cycle | 100.000 (220V AC/4 A/880VA cosÃâ= 0.35), 500.000 (220V AC/1.7 A/375VA cosÃâ= 0.6), 1.000.000 (30V DC/2 A/60 W), 2.000.000 (10V DC/0.01 A/0.1 W) |
| Number of outputs, signalling function, delayed, with contact | 0 |
| With feedback circuit | Yes |
| Suitable for monitoring of magnetic switches | Yes |
| Suitable for monitoring of proximity switches | Yes |
| Suitable for monitoring of emergency-stop circuits | Yes |
| Suitable for monitoring of optoelectronic protection equipment | Yes |
| Suitable for monitoring of position switches | Yes |
| Suitable for monitoring of tactile sensors | Yes |
| Suitable for monitoring of valves | Yes |
| Switching current, min | 10 mA |
| Switching voltage, min | 10 V |
| Rated impulse withstand voltage | 2500 V |
| Input simultaneity | Infinite |
| Safety inputs | 1 N.C., 2 N.C., light curtain |
| Operating voltage range | 24V AC/DC, 0.85 to 1.1 x rated voltage 50 60 Hz |
| SIL according to IEC 61508 | 3 |
| With approval according to UL | Yes |
| Stop category according to IEC 60204 | 0 + 1 |
| Performance level according to EN ISO 13849-1 | Level e |
| Type of safety according to IEC 61496-1 | 4 |
| With approval for BG BIA | Yes |
| With approval for TUV | Yes |
| With detachable clamps | Yes |
| Rated control supply voltage at AC 50 Hz | 24 V |
| Rated control supply voltage at AC 60 Hz | 24 V |
| Terminal protection | IP20, DIN 0470 |
| Enclosure type rating | IP40 (NEMA 1), DIN 0470 |
| Weight | 350 g |
| Vibration | 10…55 Hz, 0.35 mm |
| Shock | 10 G, 16 ms, 100 shocks |
| Rail mounting possible | Yes |
| Response time | 15 ms |
| Recovery time | 100 ms |
| Time delay range | 0.15 s |
| Enclosure protection | IP40 (NEMA 1) |
| Operating temperature | -5 ðC |
| Relative humidity | Operating: 90% RH |
| Pollution degree | 2 |
| PFHd | 0.00000000238 |
| Category | Instantaneous: 4 |
| DC | IEC 61508/IEC 62061: Instantaneous: 90% |
| T cycle | 8/28800 (h/s) |
| MTTFd | Instantaneous: 295 |
| DC avg | EN ISO 13849-1: Instantaneous: 90% |
| Mission time | 20 year |
| Hours of operation | 24 h |
| Days of operation | 365 Days |
| Height | 99 mm |
| Width | 45 mm |
| Depth | 114.50 mm |
| Mounting | 35 mm DIN rail in enclosure to a min of IP54 |
| Reset | Manual monitored or automatic/manual |