function display |
3 LED, green |
|---|---|
creepage distances and clearances between the circuits |
EN 60664-1 |
protection degree according to DIN EN 60529 (housing) |
IP40 |
protection degree according to DIN EN 60529 (terminals) |
IP20 |
ambient temperature min. |
-25 °C |
ambient temperature max. |
65 °C |
wire ranges screw terminals, fine-stranded / solid |
1 x 0.2 mm² – 2.5 mm² / 2 x 0.2 mm² – 1.0 mm² |
wire ranges screw terminals,fine-stranded with ferrules |
1 x 0.25 mm² – 2.5 mm² / 2 x 0.25 mm² – 1.0 mm² |
permissible torque min. |
0.5 Nm |
permissible torque max. |
0.6 Nm |
tightening moment |
0.6 Nm |
weight |
0.25 kg |
standards |
EN ISO 13849-1EN 62061, EN 81-1EN 50156-1; EN 62061; EN 81-1; EN 50156-1 |
suitable for safety functions |
yes |
with muting function |
no |
feedback circuit |
yes |
start contact |
yes |
stop category acc. to IEC 60204 |
0 |
rail mounting possible |
yes |
detachable clamps |
yes |
|---|---|
type of electric connection |
screw connection |
category (ISO 13849-1) |
4 |
|---|---|
PL (ISO 13849-1) |
Level e |
SILCL (IEC 62061) |
3 |
PFDd (Low demand mode) |
6.7 E-6 |
PFHd (High demand mode) |
8.5 E-9 1/h |
HFT |
1 |
SSF |
99.5 % |
DC |
99 % |
MTTFd |
132 a |
TM |
20 a |
proof test intervall (High demand mode) |
20 a |
model |
basic device |
|---|---|
suitable for monitoring of magnetic switches |
yes |
suitable for monitoring of proximity switches |
yes |
suitable for monitoring of emergency-stop circuits |
yes |
suitable for monitoring of optoelectronic protection equipment |
yes |
suitable for monitoring of position switches |
yes |
enabling paths |
normally open contact |
|---|---|
signaling paths |
opener |
contact material |
Ag alloy, gold-plated |
rated switching voltage, enabling paths AC |
230 V |
rated switching voltage, enabling paths DC |
24 V |
rated switching voltage, signaling paths AC |
230 V |
max. thermal current Ith, enabling paths |
8 A |
max. total current I² of all current path |
10 A² |
application category AC-15 (NO) |
Ue 230V, Ie 5A |
application category DC-13 (NO) |
Ue 24V, Ie 5A |
short-circuit protection (NO), max. fuse insert |
6 A class gG fuse, fuse integral < 100 A²s |
mechanical life |
107 switching cycles |
outputs, signalling function, undelayed, with contact |
0 |
outputs, signalling function, delayed, with contact |
0 |
outputs, safe, undelayed, with contact |
4 |
outputs, safe, delayed, with contact |
0 |
nominal output voltage DC |
24 V |
|---|---|
input current (safety circuit / reset circuit) |
25 mA |
max. peak current (safety circuit / reset circuit) |
100 mA |
response time tA1 |
350 ms |
response time tA2 |
350 ms |
min. switch-on time |
100 ms |
recovery time tW |
750 ms |
release time tR |
10 ms |
permissable test pulse time tTP |
< 1 ms |
max. resistivity, per channel |
≤ (5 + (1.176 x UB / UN – 1) x 100) Ω |
type of switch function of the inputs |
normally open contact |
evaluation inputs |
2-channel |
nominal voltage UN |
AC 115-120 V |
|---|---|
rated consumption AC |
2.5 VA |
rated frequency min. |
50 Hz |
rated frequency max. |
60 Hz |
electrical isolation supply circuit – control circuit |
yes |
min. rated control supply voltage at AC 50 Hz |
97.8 V |
max. rated AC voltage for controls, 50 Hz |
132 V |
min. rated DC voltage for controls |
97.8 V |
rated control supply voltage at AC 60HZ |
97.8 V |
rated control supply voltage at AC 50HZ |
132 V |
depth |
114 mm |
|---|---|
width |
22.5 mm |
height |
96.5 mm |
ECLASS 11 |
|
|---|---|
ECLASS 8.1 |
27371819 |
ETIM 9.0 |
EC001449 |
ETIM 8.0 |
EC001449 |
ETIM 7.0 |
EC001449 |
ETIM 6.0 |
EC001449 |
ETIM 5.0 |
EC001449 |
ETIM 4.0 |
EC001449 |
ETIM 3.0 |
EC001449 |
ROHS conformity status |
compliant/exempted |
|---|---|
ROHS exceptions |
III-6(c) |
REACH-SVHC conformity status |
Duty-To-Declare |
REACH-SVHC substances |
Lead |
REACH-SVHC CAS numbers |
7439-92-1 |