ALLEN BRADLEY
1516 sonuçtan 141-160 arası gösteriliyorEn yeniye göre sıralandı
-

Solid State Contactor, 43 Amperes, Open Type, 600V AC, 5 to 32V DC – 156-C1P43NCD
-

Three Phase Solid State Contactor with three switched poles 40 amps @ 40 C 600 volts AC maximum with AC control 20 – 275 volts and DC control of 24 – 190 volts. – 156-C3P40NCBA
-

Single Phase Solid State Contactor 20 amps @ 40 C 240 volts AC maximum with AC control 20 – 275 volts and DC control of 24 – 190 volts. – 156-C1P20NAB
-

Three Phase Solid State Contactor with two switched poles 25 amps @ 40 C 600 volts AC maximum with AC control 20 – 275 volts and DC control of 24 – 190 volts. – 156-C2P25NCB
-

Single Phase Solid State Contactor 20 amps @ 40 C 600 volts AC maximum DC control 5 to 32 V DC – 156-C1P20NCD
-

Replacement cooling fan for 156-C2P75 & 156-C3P65 Solid State Contactors – 156-CRF65
-

Shunt Resistor – 2097-R4
-

Safety Contactor, 9 A, IEC, 24V 60 Hz, 24V AC 60 Hz, 3 Normally Open Power Poles, 0 Normally Open Contacts And 5, Line Side Coil Termination, Bifuracated Contact – 100S-C09J05BC
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C09KF23BC
-

Safety Contactor, 9 A, 24V50/60Hz/24VDC Elec Cl, 3 NO Pwr Poles & 1 NC Pwr Pole, 24V DC Electronic, 3 NOC & 1 NCC, Line Side Coil Termination, Standard Contact – 100S-C09EJ331C
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Standard Contact – 100S-C09KF23C
-

Safety Contactor, 9 A, 24V50/60Hz/24VDC Elec Cl, 3 Normally Open Power Poles, 24V DC Electronic, 1 NOC & 4 NCC, Load Side Coil Termination, Standard Contact – 100S-C09UEJ14C
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 4 Poles, 0 Normally Open Contacts And 4, Line Side Coil Termination, Standard Contact – 100S-C09KF404C
-

Safety Contactor, 60 A, 110V 50 Hz/120V 60 Hz., 3 Normally Open Power Poles, 2 NOC & 2 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C60D22BC
-

Safety Contactor, 9 A, 240V 50 Hz/277V 60 Hz, 3 Normally Open Power Poles, 1 NOC & 4 NCC, Line Side Coil Termination, Standard Contact – 100S-C09T14C
-

Safety Contactor, 9 A, 400-415V 50 Hz, 400-415V AC 50 Hz, 3 Normally Open Power Poles, 0 Normally Open Contacts And 5, Line Side Coil Termination, Standard Contact – 100S-C09G05C
-

Safety Contactor, 9 A, 110V 50 Hz/120V 60 Hz., 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C09D23BC
-

Safety Contactor, 9 A, 24V 50 Hz, 24V AC 50 Hz, 3 NO Pwr Poles & 1 NC Pwr Pole, 0 Normally Open Contacts And 4, Line Side Coil Termination, Bifuracated Contact – 100S-C09K304BC
-

Safety Contactor, 9 A, 400-415V 50 Hz, 400-415V AC 50 Hz, 3 Normally Open Power Poles, 1 NOC & 4 NCC, Line Side Coil Termination, Standard Contact – 100S-C09G14C
-

Safety Contactor, 9 A, 110V 50 Hz/120V 60 Hz., 3 Normally Open Power Poles, 3 NOC & 2 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C09D32BC