
ALLEN BRADLEY
84 sonuçtan 61-80 arası gösteriliyorEn yeniye göre sıralandı
-

Power Supply, Bulletin 1606 XLS Performance, 200-240VAC Input, 48-56VDC Output, 960 Watt, 20A Output – 1606-XLS960FE
-

Power Supply, Redundancy Module, 12-28V DC-Input, 24V, 40A – 1606-XLSRED40HE
-

ArmorPower 24V DC Power Supply – 1607-XT200D1B
-

XLD DC DC Dönüştürücü 240W 10A – 1606-XLDD240E
-

Power Supply, Bulletin 1606 XLS Performance, 100-240VAC or 110-150VDC Input, 48-56VDC Output, 240Watt, 5A Output, Parallel Operation, DC OK Relay – 1606-XLS240F
-

1609 UPS Accessory – 1609-500SBAT
-

Side Mounting Bracket 37mm width – 1606-XLA-S37
-

Power Supply, Bulletin 1606 XLP Compact, 100-240VAC or 110-300 VDC Input, 24-28VDC Output, 30Watt, 1.3A Output, Parallel Operation – 1606-XLP30EQ
-

Power Supply, 240 W, 48V DC, No Special Function, Essential Line – 1606-XLE240F
-

Current Transformer, Accessory, 5 A, Current Relay – 809S-CT4
-

809S MachineAlert, Current Transformer » 5 A Secondary, 17 » 200 A Trip Current Range, 300 A Continuous, 1400 A Inrush, Used with 809S-C1 Current Relay – 809S-CT2
-

809S MachineAlert, Current Transformer » 5 A Secondary, 42 » 500 A Trip Current Range, 750 A Continuous, 3500 A Inrush, Used with 809S-C1 Current Relay – 809S-CT3
-

813S MachineAlert, 1-Phase, Voltage Monitoring Relay, 2 v 500V AC/DC, 115/230V AC Control Power, Under & Overvoltage Protection, SPDTContact, Adjustable Time Delay, Programmable Latch or Inhibit at Set Level, Auto Reset – 813S-V1-500V-230
-

Single-Phase Voltage Monitoring Relay, 2–500V AC/DC (Type V1), 24/48V AC/DC (Type V1 only) – 813S-V1-500V-48
-

813S MachineAlert, 3-Phase, Voltage Monitoring Relay, 110-115V AC, Self-Powered, 50 √ 400 Hz, Under & Overvoltage Protection, 2-SPDT Contact, Adjustable Time Delay, Phase – Loss/Imbalance/Reversal Protection, Programmable Latch or Inhibit at Set Level – 813S-V3-110V
-

813S MachineAlert, 3-Phase, Voltage Monitoring Relay, 208-240V AC, Self-Powered, 50 √ 400 Hz, Under & Overvoltage Protection, 2-SPDT Contact, Adjustable Time Delay, Phase – Loss/Imbalance/Reversal Protection, Programmable Latch or Inhibit at Set Level – 813S-V3-230V
-

813S MachineAlert, 3-Phase, Voltage Monitoring Relay, 440-480V AC, Self-Powered, 50 √ 400 Hz, Under & Overvoltage Protection, 2-SPDT Contact, Adjustable Time Delay, Phase – Loss/Imbalance/Reversal Protection, Programmable Latch or Inhibit at Set Level – 813S-V3-480V
-

813S MachineAlert, 3-Phase, Voltage Monitoring Relay, 600-690V AC, Self-Powered, 50 √ 400 Hz, Under & Overvoltage Protection, 2-SPDT Contact, Adjustable Time Delay, Phase – Loss/Imbalance/Reversal Protection, Programmable Latch or Inhibit at Set Level – 813S-V3-690V
-

809S MachineAlert, Current Transformer » 5 A Secondary, 4.2 » 50 A Trip Current Range, 75 A Continuous, 350 A Inrush, Used with 809S-C1 Current Relay – 809S-CT1
-

Power Bus Power Supply Feed Module – 931A-FM