Safety Limit Switch, 22mm Plastic, Roller Plunger, 2 N.C., 1 N.O., BBM, M20 Conduit – 440P-CRPB12B
-

Safety Contactor, 9 A, 12V DC (Electronic Coil), 3 Normally Open Power Poles, 12V DC Electronic, 2 NOC & 3 NCC, Line Side Coil Termination, Standard Contact – 100S-C09EQ23C
-

Safety Contactor, 9 A, 24V 50/60 Hz, 24V AC 50/60 Hz, 3 Normally Open Power Poles, 3 NOC & 2 NCC, Line Side Coil Termination, Standard Contact – 100S-C09KJ32C
-

Safety Contactor, 9 A, 48V DC (Electronic Coil), 3 Normally Open Power Poles, 48-72V DC Electronic, 0 Normally Open Contacts And 5, Line Side Coil Termination, Standard Contact – 100S-C09EY05C
-

Safety Contactor, 9 A, 200-220V 50 Hz/208-240V 60 H, 208-240V AC 60 Hz, 4 Poles, 0 Normally Open Contacts And 4, Line Side Coil Termination, Bifuracated Contact – 100S-C09L404BC
-

Safety Contactor, 9 A, 24V 50/60 Hz, 24V AC 50/60 Hz, 4 Poles, 0 Normally Open Contacts And 4, Line Side Coil Termination, Bifuracated Contact – 100S-C09KJ404BC
-

Safety Contactor, 9 A, 48V DC (Electronic Coil), 3 Normally Open Power Poles, 48-72V DC Electronic, 2 NOC & 3 NCC, Line Side Coil Termination, Standard Contact – 100S-C09EY23C
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 0 Normally Open Contacts And 5, Line Side Coil Termination, Standard Contact – 100S-C09KF05C
-

Safety Contactor, 9 A, 24V 50/60 Hz, 24V AC 50/60 Hz, 4 Poles, 2 NOC & 2 NCC, Line Side Coil Termination, Standard Contact – 100S-C09KJ422C
-

Safety Contactor, 9 A, IEC, 24V 50/60 Hz, 24V AC 50/60 Hz, 3 Normally Open Power Poles, 1 NOC & 4 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C09KJ14BC
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 1 NOC & 4 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C09KF14BC
-

Safety Contactor, 9 A, 24V50/60Hz/24VDC Elec Cl, 3 NO Pwr Poles & 1 NC Pwr Pole, 24V DC Electronic, 0 Normally Open Contacts And 4, Line Side Coil Termination, Bifuracated Contact – 100S-C09EJ304BC
-

Safety Contactor, 16 A, 110V 50 Hz/120V 60 Hz., 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C16D23BC
-

Safety Contactor, 9 A, IEC, 24V 50/60 Hz, 24V AC 50/60 Hz, 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Standard Contact – 100S-C09KJ23C
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 1 NOC & 4 NCC, Load Side Coil Termination, Standard C ontact – 100S-C09UKF14C
-

Safety Contactor, 9 A, IEC, 24V 60 Hz, 24V AC 60 Hz, 3 Normally Open Power Poles, 0 Normally Open Contacts And 5, Line Side Coil Termination, Bifuracated Contact – 100S-C09J05BC
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Bifuracated Contact – 100S-C09KF23BC
-

Safety Contactor, 9 A, 24V50/60Hz/24VDC Elec Cl, 3 NO Pwr Poles & 1 NC Pwr Pole, 24V DC Electronic, 3 NOC & 1 NCC, Line Side Coil Termination, Standard Contact – 100S-C09EJ331C
-

Safety Contactor, 9 A, 230V 50/60 Hz, 230V AC 50/60 Hz, 3 Normally Open Power Poles, 2 NOC & 3 NCC, Line Side Coil Termination, Standard Contact – 100S-C09KF23C
-

Safety Contactor, 9 A, 24V50/60Hz/24VDC Elec Cl, 3 Normally Open Power Poles, 24V DC Electronic, 1 NOC & 4 NCC, Load Side Coil Termination, Standard Contact – 100S-C09UEJ14C