USB connection for easy configuration of the SIG200 Sensor Integration Gateway with SOPAS ET, the engineering tool from SICK
Logic editor is available for easy configuration of logic functions
Items supplied
SIG200-0A0G12200, 4x blind plugs (M12) on port S2, S3, S4, P2, 1x blind plug (M8) on port CONFIG, Marking labels, quickstart
Mechanics/electronics
Connections
IO-Link
4 x M12, 5-pin female connector, A-coded
Power
1 x M12, 4-pin plug, A-coded
CONFIG
1 x M8, 4-pin female connector, USB 2.0 (USB-A)
Ethernet
2 x M12, 4-pin female connector, D-coded
Power voltage supply
Supply voltage
10 V DC … 30 V DC
Current consumption
≤ 175 mA (At supply voltage 24 V DC)
≤ 3,000 mA
Optical indicators
4 LED green (To the IO-Link ports, Pin4 (C/DI/DO))
4 LED yellow (To the IO-Link ports, Pin2 (DI))
2 LED green (To the Ethernet ports)
1 LED green (For the Power Port)
1 LED green
Input/output characteristics
S1-S4 pin 1 voltage supply
≤ 500 mA
S1-S4 pin 4 output current
≤ 200 mA
Power Port pin 4 output voltage HIGH
VH ≥ VUS – 3 V
S1-S4 pin 2 input voltage
Type 3 IEC 61131-2
S1-S4 pin 4 input voltage
Type 1 IEC 61131-2
Enclosure rating
IP67
Protection class
III
Housing material
Zinc
Housing color
Light blue/Black
Weight
520 g
Dimensions (L x W x H)
213.9 mm x 57 mm x 38.3 mm
UL File No.
E497722
Interfaces
Communication interface
IO-Link, USB, Ethernet, REST API
Logic editor
✔
Web server
✔
IO-Link Master
Function
The SIG200 Sensor Integration Gateway is an IO-Link master with 4 configurable ports to which IO-Link device as well as binary switching sensors and actuators can be connected. The gateway data is made available to a PLC or cloud application via the REST API. SIG200 can also be operated as a standalone system by directly configuring simple logic functions across several connected devices via the SOPAS ET user interface.
IO-Link version
V1.1, V1.0
Port Class
A
Number of IO-Link ports
4
Transmission type
COM1, COM2, COM3
Operator interfaces
SOPAS ET, the engineering tool for configuration via USB, Additionally, the SIG200 can be configured via the integrated webserver. Default IP adress: 192.168.0.1
MAC address
See product label
Number of inputs
Max. 8 x PNP, type 1 or 4 x IO-Link
Number of outputs
Max. 4 x PNP
Max. Output frequency
50 Hz
Inputs/outputs
S1-S4
4 configurable ports Pin4 can be used in one of the available port modes: IO-Link, digital input or digital output. An additional digital input signal can be connected using Pin2.
LINK/ACT 1 & 2
Two Ethernet ports are provided for the network connection
CONFIG
Port for configuration via USB with SOPAS ET (SOPAS ET can be downloaded for free from www.sick.com)