Home Işık Perdeleri FTS-I060F14A – 1091146 🔍 FTS-I060F14A – 1091146 ✉ Teklif Al Teklif Al Stok kodu: 1091146 Kategoriler: Işık Perdeleri Marka: SICK Açıklama Tecnichal data Features Measurement principle Calorimetric measurement process Medium Water and oil-based liquids Pipe diameters ≥ 25 mm Measuring range 3 cm/s … 300 cm/s, Water 3 cm/s … 300 cm/s, Oil A / Oil B 3 cm/s … 600 cm/s, Taught-in media Process temperature –40 °C … +150 °C Process pressure –1 bar … 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50) Communication interface IO-Link, IO-Link V1.1, COM3 (230.4 kbit/s) Temperature measurement ✔ Indication ✔OLED + 3 status LEDs Performance Inlet zone 5 x DN Output zone 3 x DN Measurement accuracy ± 7 % From measured value + 2% of measuring range end value Repeatability < 1 cm/s Resolution 0.01 m/s Speed; 0.1 L/min volume; 0.1% relative (via IO-Link) Temperature drift < 0.5 cm / (s*K) Response time < 2.5 s Temperature measurement Measurement accuracy (temperature) ± 1 °C Resolution (Temperature) < 0.1 °C Response time (temperature) < 5 s Operating mode Relative speed (%), Volume flow and total volume, Relative teach (%) Electronics Supply voltage 9 V DC … 30 V DC Power consumption < 2 W at 24 V DC (without load on the outputs) < 8 W At maximum load Initialization time ≤ 5 s ≤ 10 s (IO-Link) Protection class III Connection type M12 round connector x 1, 4-pin Output signal 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature Output current < 100 mA Inductive load 1 H Capacitive load 100 nF (2.5 nF, IO-Link mode) EMC EN 61326-1, EN 61326-2-3 Digital input limit HIGH voltage dependent on Uv LOW voltage < 4.0 V MTTF > 200 years Mechanics Process connection Without process connection (adapter needed for installation) Wetted parts Stainless steel 1.4404 (Ra ≤ 0,8 µm) Housing material VISTAL® (PA66+PA6I GF50) Enclosure rating IP67 Weight 74 g Probe diameter 8 mm Probe length 60 mm Minimum immersion length 12 mm Distance to pipe wall 10 mm Ambient data Ambient operating temperature –40 °C … +70 °C Ambient temperature, storage –40 °C … +80 °C Classifications ECLASS 5.0 27273101 ECLASS 5.1.4 27273101 ECLASS 6.0 27273101 ECLASS 6.2 27273101 ECLASS 7.0 27273101 ECLASS 8.0 27273101 ECLASS 8.1 27273101 ECLASS 9.0 27273101 ECLASS 10.0 27273101 ECLASS 11.0 27273101 ECLASS 12.0 27274803 ETIM 5.0 EC002580 ETIM 6.0 EC002580 ETIM 7.0 EC002580 ETIM 8.0 EC002580 UNSPSC 16.0901 41112501 İlgili ürünler Transceiver, LineE 1050 – 30mm, Product line E, Type4/Cat.4, 30mm Hand resolution, Protective height: 1050 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4HL1050YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git GuardShield LineE 1950 – 14mm Transceiver – 450L-E4FL1950YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git Transceiver, LineE 1500 – 14mm, Product line E, Type4/Cat.4, 14mm Finger resolution, Protective height: 1500 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4FL1500YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git Transceiver, LineE 150-30mm, Product line E, Type4/Cat.4, 30mm Hand resolution, Protective height: 150 mm, Laser integrated, Enclosure rating IP65, GuardShield – 450L-E4HL0150YDALLEN BRADLEYIşık Perdeleri ₺18.000,00 Ürüne Git
Tecnichal data Features Measurement principle Calorimetric measurement process Medium Water and oil-based liquids Pipe diameters ≥ 25 mm Measuring range 3 cm/s … 300 cm/s, Water 3 cm/s … 300 cm/s, Oil A / Oil B 3 cm/s … 600 cm/s, Taught-in media Process temperature –40 °C … +150 °C Process pressure –1 bar … 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50) Communication interface IO-Link, IO-Link V1.1, COM3 (230.4 kbit/s) Temperature measurement ✔ Indication ✔OLED + 3 status LEDs Performance Inlet zone 5 x DN Output zone 3 x DN Measurement accuracy ± 7 % From measured value + 2% of measuring range end value Repeatability < 1 cm/s Resolution 0.01 m/s Speed; 0.1 L/min volume; 0.1% relative (via IO-Link) Temperature drift < 0.5 cm / (s*K) Response time < 2.5 s Temperature measurement Measurement accuracy (temperature) ± 1 °C Resolution (Temperature) < 0.1 °C Response time (temperature) < 5 s Operating mode Relative speed (%), Volume flow and total volume, Relative teach (%) Electronics Supply voltage 9 V DC … 30 V DC Power consumption < 2 W at 24 V DC (without load on the outputs) < 8 W At maximum load Initialization time ≤ 5 s ≤ 10 s (IO-Link) Protection class III Connection type M12 round connector x 1, 4-pin Output signal 2 push-pull digital outputs (Q2 configurable for IO-Link; Q2 configurable as pulse output / digital input) for flow and temperature Output current < 100 mA Inductive load 1 H Capacitive load 100 nF (2.5 nF, IO-Link mode) EMC EN 61326-1, EN 61326-2-3 Digital input limit HIGH voltage dependent on Uv LOW voltage < 4.0 V MTTF > 200 years Mechanics Process connection Without process connection (adapter needed for installation) Wetted parts Stainless steel 1.4404 (Ra ≤ 0,8 µm) Housing material VISTAL® (PA66+PA6I GF50) Enclosure rating IP67 Weight 74 g Probe diameter 8 mm Probe length 60 mm Minimum immersion length 12 mm Distance to pipe wall 10 mm Ambient data Ambient operating temperature –40 °C … +70 °C Ambient temperature, storage –40 °C … +80 °C Classifications ECLASS 5.0 27273101 ECLASS 5.1.4 27273101 ECLASS 6.0 27273101 ECLASS 6.2 27273101 ECLASS 7.0 27273101 ECLASS 8.0 27273101 ECLASS 8.1 27273101 ECLASS 9.0 27273101 ECLASS 10.0 27273101 ECLASS 11.0 27273101 ECLASS 12.0 27274803 ETIM 5.0 EC002580 ETIM 6.0 EC002580 ETIM 7.0 EC002580 ETIM 8.0 EC002580 UNSPSC 16.0901 41112501